Home>Pump>Vane Pump>Peripheral Pump>Peripheral Pump

LOADING IMAGES
}

Peripheral Pump

Item ID:69
Series
Flow
Head
Model
List Price
$450.00
Price
$293.00
Quantity
+- (500in stock)
Add to Cart Add to Wishlist
1 item added to your cart !X
Cart subtotal (X items)
View Your Cart Continue shopping

I. Overview

W single-stage vortex pump with direct connection is used for the suction and delivery of clean water and the liquid with similar physical and chemical properties to water,

and the liquid temperature shall not exceed 80 . It is commonly used in boiler water supply supporting facility and widely applied to the sectors, such as shipbuilding,

textile, chemical, metallurgy, machinery manufacturing, aquaculture, heat exchange unit, a remote agricultural spray irrigation, etc.


II. Start-up, shutdown

  • W-type pump should be firstly checked whether there are calcium-base butter in the bearing body. Open the bearing cover and check if the butter stored too long, to see whether it is metamorphic. If so, the butter should be changed and then start;
  • Rotating couplings (direct connection pump can rotate the blade after removing the blade 5 of motor). After confirming that the rotor component is rotated uniformly and easily, gradienter should be applied to examine the levelness of unit. Fasten the nut connected with bearing part after leveling;
  • Measure the insulation strength of the motor, if less than 5MΩ, the motor may be damp or damaged. If it is only because of moisture, which can dry by running for some time, otherwise, the motor must be repaired or replaced to avoid the damage to the pump brought by the dysfunctional of motor;
  • Test start-up: Start the motor, adjust the steering of motor as requirement;
  • Open the suction line valve, and guide the liquid to the pump body. If  the pump is installed above the horizontal position, foot valve can be installed at the bottom end of the suction pipe;
  • Before starting, the pump case should be filled with pumped liquid ( if suction path is short, there is no need to fill the liquid again after the first start for the remaining liquid in the pump case);
  • Open the discharge pipeline valve, start the motor, and view the gauge. Make the reading of gauge proper by adjusting the extrusion pipeline valve. It is absolutely not allowed that the pump works at the condition of closed valve or little flow;
  • When stop the pump, first shut off the gauge, stop the motor and then quickly close the extrusion and suction pipeline valves;
  • Short shutdown: If the ambient temperature is below the freezing point of the liquid, the liquid must be vented. Long-term shutdown: Pump should be cleaned, oiled and then safekeeping.


III. Operation

  • During the operation, Observe the unit operating state, especially notice the motor temperature whether is too high. Note also that the split pump bearing temperature should not exceed 70 . To solve the former problem, the pipe should be checked whether it is blocked, or the valve whether it is open. To solve the latter problem, the calcium-base butter should be checked whether it is added properly, or the bearing damaged, or motor and pump are not concentric;
  • The pump should be stopped and checked once fault occurs.


IV. Performance Parameter

Model Voltage(V) FlowQ Head Rotary Speedr/min Power KW
(m3/h) (m)
1/2W1.25-8 380 1.25 80 2900 0.75
3/4W1.44-10 380 1.44 100 2900 1.5
1W2.4-10.5 380 2.4 105 2900 3
1W2.5-12 380 2.5 120 2900 3
20W-20 380 0.72 20 2900 0.75
20W-65 380 0.72 65 2900 2.2
25W-25 380 1.44 25 2900 0.75
25W-70 380 1.44 70 2900 3
32W-30 380 2.88 30 2900 1.5
32W-75 380 2.88 75 2900 4
32W-120 380 3.88 120 2900 5.5
40W-40 380 5.4 40 2900 4
40W-90 380 5.4 90 2900 7.5
50W-45 380 9 45 2900 5.5
65W-50 380 14.4 50 2900 11
1.5DB-0.7 380 2.4 105 1450 3